ADTRAN TA 544 Network Card User Manual


 
TA 544 User Manual/61200704L1-1A
Page 53 of 68
© 2001, ADTRAN, Inc. TA 544 User Manual
3. Select XMODEM for T
RANSFER
M
ETHOD
.
4. Press
Enter
on S
TART
T
RANSFER
<+>.
5. When prompted, press
Y
to erase flash.
6. From the terminal emulation software, begin the XMODEM upload by using the appropriate
command sequence. (If necessary, refer to terminal emulation software documentation for
help. Also, when specifying the filename, ensure that the file transferred is the one pro-
vided by ADTRAN. Otherwise, the update will not complete successfully.)
7. When the update has successfully completed, T
RANSFER
C
OMPLETE
displays in T
RANSFER
S
TATUS
. The module restarts immediately and resumes operation. If an error occurs during
the update, an error message will display in the T
RANSFER
S
TATUS
field. If this occurs, return
to Step 3 and attempt the update again. If the same error occurs, contactADTRAN Techni-
cal Support.
When TA 544 is ready to receive the XMODEM upload, the menu screen will clear and display
Transmit Flash . . . download file now
. If this does not appear, please review the steps above for
possible configuration errors.
Because XMODEM data is being transferred in-band through the menu interface, the VT 100
menus of TA 544 will be inoperable from the
CRAFT
port.