Agilent Technologies J3916A Computer Hardware User Manual


 
Probe Operation
Restarting the Probe
95
Cold Start
A cold start resets all of the probe’s measurement data as well as all alarm, event,
filter, and user-defined statistics configuration to their default values. Basic
communications configuration parameters (IP address, default gateway IP
address, and subnet mask) are not reset.
You can cold start the probe by doing one of the following:
Pressing the CONFIG Button twice within one second.
Selecting the menu item
Cold start and Exit
from the probe’s Main Menu
when you have a local terminal connected to the probe, as described on
page 96.
Using Agilent NetMetrix to execute a probe cold start. Refer to your
NetMetrix documentation for details.
Table 5-1 on page 92 shows which data and parameters are reset during a cold
start or warm start of the probe.
Pressing the CONFIG Button Twice
Pressing the CONFIG button twice within one second causes the probe to cold
start.