Agilent Technologies J3916A Computer Hardware User Manual


 
Local Terminal Configuration
Using the Main Menu
28
The Telemetry port only receives packets destined to the
telemetry port’s IP address, can transmit packets onto the
network, and is used for SNMP communications to the probe.
It requires the IP Address, Subnet Mask, and Default
Gateway IP Address fields. The following apply to Telemetry
ports:
HP OpenView can discover the interface
The interface is IP addressable
The interface responds to RMON-1
The interface will transmit all traps from the probe
The interface will transmit all extended RMON packets
sample from Monitor-only ports, Monitor/Transmit ports.
IP Address Press
3
and then type the IP address for the probe. If the IP
address is 0.0.0.0, the probe will transmit Bootp Requests
for configuration information (including IP address) over the
network. (This does not apply to ports configured as Monitor-
Only.)
Default Gateway Press
4
and then type the default gateway IP address for the
probe
IP Address Optional
Subnet Mask Press
5
and then type the subnet mask for the probe.
Physical Press
6
and choose a physical connector. The menu displays
Connector the physical connectors that are available. You can use the
RJ-45 or AUI connector. If you select AUI, items 7 and 8
(Link Speed and Full/Half Duplex) are not available. AUI is
10MB/s half-duplex.
CAUTION
If you manually select the Link Speed, be careful to configure it correctly. If you
configure the Link Speed for 100 MB/s and you connect the probe to a
10MB/s network, the probe will generate 100% utilization for that segment.