Allied Telesis Patch 89262-08 Switch User Manual


 
Patch 89262-08 For AT-8900 Series Switches 11
Patch 89262-08 for Software Release 2.6.2
C613-10402-00 REV H
Features in 89262-06
Patch file details are listed in Table 3.
Patch 89262-06 includes all issues resolved and enhancements released in
previous patches for Software Release 2.6.2, and the following enhancements:
While the switch was set with a CIDR interface address, when it received an
ECHO request with a network broadcast destination address for a class C
network, the switch sent the ECHO reply packet. Also, the switch
forwarded the ECHO request packet using a broadcast MAC address. These
issues have been resolved.
When the device operated in NTP Client mode, the SHOW TIME command
sometimes displayed the incorrect time. This issue has been resolved.
Total exception errors occurred when the OSPF DEFAULTROUTE was set
to from ON to OFF. This problem has been resolved.
OSPF did not refresh a network LSA when it received a LSA with errors
from another vendor’s device. This has now been fixed.
PIM counters were not totalling up correctly for erroneous packets if the
type of PIM packet was not known. This issue has been resolved.
Out of sequence IPSEC packets could cause a switch reboot. This issue has
been resolved.
When PIM-SM was configured and a very large number of IGMP v2 joins
were received, a switch reboot could occur. This issue has been resolved.
When expirykbytes was set to a low value in the IPsec policy, it was
possible that a memory leak could occur if heavy IPsec traffic was being
Table 3: Patch file details for Patch 89262-06.
Base Software Release File
89-262.rez
Patch Release Date
12-Aug-2004
Compressed Patch File Name
89262-06.paz
Compressed Patch File Size
274040 bytes
PCR: 31225 Module: IPG Level: 3
PCR: 40008 Module: NTP Level: 3
PCR: 40075 Module: OSPF Level: 2
PCR: 40123 Module: OSPF Level: 2
PCR: 40261 Module: PIM4 Level: 4
PCR: 40266 Module: IPSEC Level: 2
PCR: 40284 Module: PIM Level: 2
PCR: 40321 Module: ENCO, IPSEC Level: 2