When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the
opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be
centered within this opening.
F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have ALL electrical connections made by a properly licensed and competent
electrician to ensure that the electrical installation is adequate and conforms to local and state regulations or
codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must
conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST
EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual, can result in PERSONAL INJURY OR COMPONENT FAILURE.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
A separate circuit servicing each basket (tumbler) must be provided. The dryer must be connected to
copper wire ONLY. DO NOT use aluminum wire, it could create a fire hazard.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
2. Electrical Connections
A wire diagram is included with each dryer showing the wiring connection sequence. The electrical
connections are made in the wiring box located at the rear top area of the dryer.
Each pocket must be provided with a separate circuit. The external power connection for the top pocket
is made to a terminal block and the lower external power connection is made to a wire harness; both are
located in the above mentioned wire box.