American Dryer Corp. AD-360X2RD Computer Monitor User Manual


 
22
H. PREPARATION FOR OPERATION
The following items should be checked before attempting to operate the dryer:
1. Read ALLCAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.
3. Check to ensure that the dryer is connected to the type of heat/gas indicated on the dryer data label.
4. The sail switch damper assembly was installed and adjusted at the factory prior to shipping. However,
each sail switch adjustment must be checked to ensure that this important safety control is functioning.
5. Check bolts, nuts, screws, terminals, and fittings for tightness.
6. Be sure that ALL gas shutoff valves are in the open position.
7. Be sure ALL back guard panels and service box covers have been replaced.
8. Check the lint drawer to ensure that it is closed and secured in place.
9. Rotate the basket (tumbler) by hand to be sure they move freely.
I. PREOPERATIONAL TEST
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit.
1. Turn on electric power to the dryer.
Open ALL gas shutoff valves.
2. Computer System Operational Test
a. Coin Models
1) The liquid crystal display (L.C.D.) screen reads “Ready,” insert amount to start (i.e. 25¢).
2) Insert coin(s). Once the correct amount has been inserted, the display for the appropriate pocket
will display “SELECT TEMP TO START.”
3) Start temperature by pressing “HIGH,” “MEDIUM,” or “LOW” for the dryer pocket you wish to
start the cycle in. The cycle/dryer will start, and the L.C.D. will read the drying cycle selected, and
the remaining time.
4) The dryer will continue through the drying and cooling cycles until the time vended has expired.
NOTE: The dryer can be stopped at any time by opening the main loading door. To restart the dryer,
press appropriate temperature selection key.