American Dryer Corp. AD-360X2RD Computer Monitor User Manual


 
30
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN
CREATE A POTENTIAL FIRE HAZARD.
WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION
AIR.
WARNING: INSPECT AND REMOVE ANY LINT ACCUMULATION, WHICH CAN
CAUSE THE BACK DRAFT DAMPER TO BIND OR STICK.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of
the heat circuit safety switches and/or thermostats.
NOTE: When cleaning dryer cabinet(s), avoid using harsh abrasives. A product intended for the
cleaning of appliances is recommended.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, setscrews, grounding connections, nonpermanent gas connections (unions, shutoff
valves, and orifices) and examine wheels. Motor and drive belts should be examined. Cracked or seriously
frayed belt(s) should be replaced. Tighten loose belts when necessary. Complete operational check of controls
and valves. Complete operational check of ALL safety devices (door switches, lint drawer switch, sail switch,
burner and hi-limit thermostats).
C. LUBRICATION
The motor bearings and under normal conditions the basket (tumbler) bearings are permanently lubricated.