1.4 Environmental Standards
Table 1.2: Environmental Standards
Environmental Operational Parameters
Operation
Temperature
0° C to 50° C -10° C to 55° C*
* Battery mode:
0°C @ 50% Battery capacity.
* Adapter mode: Any
( MIL-STD 810F Methods 501.4 and 502.4 )
Storage Temperature
-20° C to 60° C -40° C to 75° C
( MIL-STD 810F Methods 501.4 and 502.4 )
Thermal Shock
1.5° C < 5° C / minute over 0° C
to 50° C verified during
MILSTD810F testing
1.5°C < 5° C / minute over -10° C
to 55° C verified during
MILSTD810F testing
Operational Humidity
0% to 95% non-condensing MIL-STD810F Method 507.4
Storage Humidity
0% to 95% non-condensing MIL-STD810F Method 507.4
IP Rating
IP-54
Drop
3 foot high free drop survival limit, (test surface: concrete, base unit
only). According to MIL-STD-810F, Method 516.5
Shock and Pressure
Mechanical Shock
20g, 11ms, Terminal sawtooth, operating.
40g, 11ms, Terminal sawtooth, non-operating
MIL-STD-810F method 516.5
Vibration
- Operation
By CF: MIL-STD 810F Methods 514.5C-3
By HDD: MIL-STD 810F Methods 514.5C-1
- Non-operation
0.04g^2/Hz, 20Hz - 1000Hz, -6dB/octave 1000Hz - 2000Hz,
MIL- STD-810F method 514.5C-17
Low Pressure
-15,000 ft.: in accordance with MIL-STD810F; Method 500.4, Proce-
dure I
Agency Approvals
EMC
- EN55022 Class B
- EN55011 Class A
- FCC Part15 Class B
- DOC Class B
EMS
- Contact: 4Kv/ Air: 8Kv, EN55024
Safety
- UL / cUL, UL60950-1
- CB, IEC/EN60950-1