Chapter 4 Installation
Avaya P332GT-ML User’s Guide 21
To connect stacked switches:
Note: When adding a module to an existing stack, first connect the stacking cables
and then power up the module.
1 Plug the light grey connector of the Short Octaplane cable into the port marked
“to upper unit” of the bottom P330 Family module.
2 Plug dark grey connector of same Short Octaplane cable to the port marked “to
lower unit” in the unit above. The connections are illustrated in Figure 4.3.
3 Repeat Steps 1 and 2 until you reach the top switch in the stack.
4 If you wish to implement stack redundancy, use the Redundant Cable to
connect the port marked “ to lower unit” on the bottom switch to the port
marked “to upper unit” on top switch of the stack.
5 Power up the added modules.
Caution: Do not cross connect two P330 switches with two Octaplane (light-colored)
cables. If you wish to cross-connect for redundancy, use one light-colored Octaplane
cable and one black redundancy cable. Figure 4.2 shows an incorrect connection.
Note: You can build a stack of up to 10 P330 switches (any mixture of P330 and
P330-ML modules wihin a stack is possible). If you do not wish to stack all the
switches in a single rack, use long Octaplane cables to connect two physical stacks
as shown in Figure 4.3.
Figure 4.2 Incorrect Stack Connection