Multiuser operation in a multiple switch system
In a multiple switch system, users will operate in independent access mode.
Both users can simultaneously and independently access any computer
attached to the primary AutoView unit. Similarly, independent access is
possible across the cascaded units as long as each user is accessing a different
secondary unit.
Multiple Switch Access Example
Figure 4.3: Independent Operation in a Multiple Switch System
User 1 is working on channel 4 of the secondary unit A. User 2 wants to access channel C4.
Behavior: User 2 can be independently using any computer attached to the primary unit or to
secondary unit C. User 2 cannot independently access any computer attached to secondary unit
A until the first user connects to a computer attached to a different unit.
Keyboard Translation
The AutoView 424 allows you to use PS/2 or Sun keyboards to operate any
type of attached computer. However, when crossing platforms, certain keys
will need to be remapped in order to provide all of the functions available on
the keyboard native to that platform.
For example, if you access a Sun workstation with a PS/2 keyboard, you will
notice that the PS/2 keyboard does not have the Stop and Again keys that are
on a true Sun keyboard. But, by turning Scroll Lock on, the F1 and F2 keys on
the PS/2 keyboard function as the Sun Stop and Again keys. With Scroll Lock
off, F1 and F2 function normally.
3
Secondary Unit C
Secondary Unit A
C1 C2 C3 C4
A1 A2 A3 A4
Primary Unit
User 1 User 2
4