Baracoda BCM 2604 Barcode Reader User Manual


 
EXAMPLE: Decode only those bar codes with a count of 9-20 characters.
Min. length = 09 Max. length = 20
EXAMPLE: Decode only those bar codes with a count of 15 characters.
Min. length = 15 Max. length = 15
For a value other than the minimum and maximum message length defaults, scan the bar codes
included in the explanation of the symbology, then scan the digit value of the message length and
Save bar codes on the Programming Chart (Appendix E of this manual). The minimum and maximum
lengths and the defaults are included with the respective symbologies.
3.4 Codabar
<Default All Codabar Settings>
Codabar Start/Stop Characters
3.4.1 Codabar Check Character
Default = Dont Transmit
3.4.2 Codabar Check Character
Codabar check characters are created using different modulos. You can program the imager to
read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character.
14