3.5.3 Code 39 Message Length
Scan the bar codes below to change the message length. Refer to Message Length Description
(chapt 3.2) for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0,
Maximum Default = 48.
3.5.4 Code 39 Append
This function allows the imager to append the data from several Code 39 bar codes together before
transmitting them to the host computer. When this function is enabled, the imager stores those Code
39 bar codes that start with a space (excluding the start and stop symbols), and does not
immediately transmit the data. The imager stores the data in the order in which the bar codes are
read, deleting the first space from each. The imager transmits the appended data when it reads a
Code 39 bar code that starts with a character other than a space. Default = Off.
3.5.5 Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This
symbology is also known as PARAF.
Note: Trioptic Code must be turned off while scanning Code 32 Pharmaceutical codes.
3.5.6 Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will
be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN,
and /C will be decoded as the ASCII character #. Default = On.
17
Minimum Message Length
Maximum Message Length
* Off
On