Barco R5075236_r03 Projector User Manual


 
3-84 3-84user's manual R5975236-r3 user's manual R5975236-r3
Chapter 3: Advanced commands
Chapter 3: Advanced commands
Description :
Read the actual shutter position (OPTIONAL).
Command :
Command[0] \x21
Command[1] \x42
Data :
No data bytes.
Return data :
Data[0] = shutter position.
Data[0]
Closed \x00
Open \x01
Undetermined \x02
Projector type :
BD2100, BD2100LC, BD3000, BD3000LC, BD3100
V1.06
, BD3100LC
V1.06
,
BD5100
V1.06
, BD5100LC
V1.06
, BD8100
V1.06
, BD8100LC
V1.06
, BG8100, BG8100LC
Example :
Read the actual shutter position of a projector with address \x01. Suppose the
shutter is open.
Transmit
Start \xfe
Projector address \x01
Command[0] \x21
Command[1] \x42
Checksum \x64
Stop \xff
shutter, read
Description :
Read the actual shutter position (OPTIONAL).
Command :
Command[0] \x21
Command[1] \x42
Data :
No data bytes.
Return data :
Data[0] = shutter position.
Data[0]
Closed \x00
Open \x01
Undetermined \x02
Projector type :
BD2100, BD2100LC, BD3000, BD3000LC, BD3100
V1.06
, BD3100LC
V1.06
,
BD5100
V1.06
, BD5100LC
V1.06
, BD8100
V1.06
, BD8100LC
V1.06
, BG8100, BG8100LC
Example :
Read the actual shutter position of a projector with address \x01. Suppose
the shutter is open.
Transmit
Start \xfe
Projector address \x01
Command[0] \x21
Command[1] \x42
Checksum \x64
Stop \xff
shutter, read