Orbiting
A-3
5975198 RETRODATA 808s 210397
Adjustment procedure multiple projector installations :
Inportant : to allow corrections in the deviation alignments of the slave
projectors, never adjust the deviations of the master projector to its
maximum.
Default setting of the Master projectorn see 'Stand-Alone projector'.
Highlight 'ADJUST DEVIATION' by pushing the control disk up or
down and press
ENTER.
When adjusting the horizontal and the vertical deviation, the picture
moves in corresponding direction, allowing the set up of the deviation
without orbiting operation.
<EXIT> to return.
SLAVE ORBITING
CHANGE TO MASTER
ADJUST DEVIATION
SELECT WITH OR
THEN <ENTERN>
DEVIATION ADJUST :
VERTICAL WITH OR
HORIZONTAL WITH OR
A
djust horizontal deviation by pushing
t
he control disk to the left or to the right
Adjust vertical deviation by pushing
the control disk up or down
Push the control disk to the right or down to toggle between Hor. and
Vert. deviation adjustment.
HORIZONTAL
ORBIT AMPL
70
VERTICAL
ORBIT AMPL
70