9. Stage Time button – in the event of a power outage, this unit provides
battery backup. To extend the battery’s ability to supply power to your
most critical home theater equipment, power can be automatically
shut off to your less critical devices first. This is the unit’s staged
shutdown feature. There are three stages and there is a calculated
amount of battery-backup time for each stage. This button enables you
to cycle through each stage and see how much usable battery-backup
time each stage has. Additionally, you can see how much battery-
backup time would be available if the staged shutdown feature were
turned off (i.e. override turned on – see “Override Stages” button).
10. Override Stages button – in the event of a power outage, this unit
automatically provides battery backup. To extend the battery’s ability
to supply power to your most critical home theater equipment, power
is automatically shut off to the less critical devices first. This button
enables you to override this staged shutdown feature and continue
supplying battery-backup power to all of the equipment connected to
your AVU1500 until the battery is completely drained or the power
outage ends.
15
19
16
18
17
20
11 12
14
13
11. Incoming voltage – this number will accurately communicate the AC
voltage coming into the unit from the AC wall outlet.
12. PureFilter On – indicates that the multiphase PureFilter circuitry
is functioning properly (i.e., power protection and conditioning).