Belkin AVU1500 Power Supply User Manual


 
Belkin PureAV Hybrid AVU1500 UPS
58
®
®
Using Your AVU1500 with a
Home Automation System (optional)
The PresentStatus in Battery System is a collection item
that includes:
BelowRemainingCapacityLimit: To indicate the battery level is
lower than the battery low limit.
Charging: The battery is charging.
Discharging: The battery is discharging.
FullyDischarged: Battery depleted.
NeedReplacement: The battery needs to be replaced.
The RemainingCapacity usage is predicted remaining capacity of
battery in percentage unit fixed.
Charging: 0: Not charge, 1: Charging.
BelowRemainingCapacityLimit (bat low): 0: Normal, 1: Battery low.
Power Status (Page 0x86)
Report ID # Usage (usage ID) Byte # Unit Comment
34
~
Ä
PresentStatus (0x21)
2
R Collection Item
}VoltageOutOfRange Bit0
}Buck Bit1
}Boost Bit2
}Unused Bit3
}Overload Bit4
}Standby Bit5
}OverTemperature Bit6
}InternalFail Bit7
}Unused Bit8
}Unused Bit9
}Unused Bit10
}Unused Bit11
}Unused Bit12
}Unused Bit13
}BuzzerSilence Bit14
}Beeper Bit15