Belkin AVU1500 Power Supply User Manual


 
Belkin PureAV Hybrid AVU1500 UPS
59
Using Your AVU1500 with a
Home Automation System (optional)
AVU Special Features (Page 0x86)
Report ID # Usage (usage ID) Byte # Unit Comment
110 Stage 1 Battery Threshold (0x29) 1 % R/W
111 Stage 2 Battery Threshold (0x29) 1 % R/W
112 Stage 3 Battery Threshold (0x29) 1 % R/W
113 Stage 1 Load Current (0x31) 1 Amps R
114 Stage 2 Load Current (0x31) 1 Amps R
115 Stage 3 Load Current (0x31) 1 Amps R
117 Site Wiring Fault (0xFC) 1 R
118 Site Ground Fault (0xFB) 1 R
119 Stage 1 Remaining Time (0xFA) 2 Sec R
120 Stage 2 Remaining Time (0xFA) 2 Sec R
121 Stage 3 Remaining Time (0xFA) 2 Sec R
122 Shutdown Override (0xF9) 1 R/W IN/Feature*
123 IR Shutdown Code Known (0xF8) 1 R IN/Feature*
124
IR Shutdown Code Broadcast at
Beginning of Stage N (0xF7)
1
Stage
Number
R
85 Source Change (0xF6)
1 IN*
86 Stage 1 startup/shutdown (0xF5) 1 R IN/Feature*
87 Stage 2 startup/shutdown (0xF5) 1 R IN/Feature*
88 Stage 3 startup/shutdown (0xF5) 1 R IN/Feature*
89 Overload (0xF2) 1 IN*
90 Battery Fully Charged (0xF1) 1 R IN/Feature*
91
Battery Needs Replacement
(0xF0)
1 IN*
92 Power Off Notification (0xFD)
1 IN*
IN* indicates this item is interrupt only, IN/Feature means this item supports both interrupt and feature.
The PresentStatus in Power Status is a collection item that includes:
VoltageOutOfRange: The input voltage is lower or beyond the
normal range. The UPS transfers to backup mode and supplies the
output power from battery.
Buck: The input power is suppressing to normal range.
Boost: The input power is boosting to normal range.
Overload: The loading beyond the rating power.
Standby: The UPS is in standby mode, which mans the UPS is not
turned on.
OverTemperature: Over temperature.
InternalFail: UPS general fail indication.
BuzzerSilence: Indicates to support buzzer enable/disable
control item.
Beeper: To indicate the UPS buzzer is silent or alarm.