Black Box MD885A-R3 Modem User Manual


 
137
Appendix C: Summary Setup
C.2 SETUPS Screen
Only part of the SETUPS screen can be
displayed at any one time. The full screen
is displayed below next to the numbers 1,
2, and 3.
To make configuration and viewing easier, the screen is broken down into a
number of sections. Use the front-panel pushbuttons to move around within
the SETUPS screen (see Figure C-2).
1
PRI addr dial eia v42<1>
0011214E0 999 999 11111002210 000100000 20334300
2
v42<2> L.L. pump1 pump2 pump3
210001021 10000010 30100101100 00000110 00000000
3
misc1 misc2 misc3
1141110 0000 001FFFF1 71000000
Primary Options:
PRI
0011214E0
Speed limit, type: 0=V.32/V.32bis, 1=V.33, 2=Bell 208
Speed limit, min. (bps): 4=19.2 K, 5=16.8 K, 6=14.4 K, 7=12.0 K, 8=9600,
9=7200, A=4800, B=2400, C=1200, D=600, E=0-300, F=1200/75
Speed limit, max. (bps): 4=19.2 K, 5=16.8 K, 6=14.4 K, 7=12.0 K, 8=9600,
9=7200, A=4800, B=2400, C=1200, D=600, E=0-300, F=1200/75, G=EIA 23
Buffer mode/speed conversion: 0=disable, 1=enable
V.42 mode: 0=off, 1=mandatory, 2=automatic
Dialer mode: 0=off, 1=Hayes, 2=DTR dialing, 3=V.25 bis–async
4=V.25bis–sync/character-oriented, 5 =V.25 bis–sync/bit-oriented
Character length (bits): 0=9, 1=10, 2=11
Data format: 0 =Async,1=Sync
Line type: 0=2-wire dial, 1=2-wire leased, 2=4-wire leased
NOTE
Speed limit, min. and Speed limit, max.: 7200 bps parameters are
available only if V.32 bis mode is enabled.
PRI addr
0011214E0 999 99
12
3