Brady 200M Printer User Manual


 
ZPL II was sent to
printer, but not
recognized. The DATA
light remains OFF.
Communications
parameters or DIP
Switches are set
incorrectly.
See the Operation Section and
perform MODE Key Self Test.
Check for format or overrun
errors. Reset Communication
parameters if needed.
Prefix and delimiter
characters set in printer
configuration do not
match the ones sent in
the ZPL II Label
Formats.
Set the characters in the printer
to match ZPL II format.
Check Configuration Label for
correct characters.
If problem continues, check
the ZPL II format for changed
^CC, ^CT, and ^CD
instructions.
260M printer does not
operate in the mode
specified in ZPL II or by
calibration
Bank 2 DIP switches set
to override ZPL II and
calibration.
Check Bank 2 DIP switch
settings.
Printer does not feed
media with black marks
correctly.
Printer not set up
correctly.
See Chapter 4—
recalibrate printer.
See Chapter 4 to check Bank 2
DIP switch settings.
Sensor is broken. (No
red light is visible when
looking through the
front of the printer with
the printhead open.)
Call a service technician.
8-5