Cabletron Systems 2E48-27R Switch User Manual


 
High Speed Interface Configuration Screen
2E48-27R/2E49-27R User’s Guide 5-51
Figure 5-23 High Speed Interface Configuration Screen
The following briefly defines each field of the High Speed Interface
Configuration screen.
Port Type (Read-only)
Displays the type of interface (FE-100FX, FE-100TX, FE-100F3, or
Unknown) installed in ports 25 and 26. Figure 5-23 shows that there is an
FE-100TX interface installed in port 25 and no interface (indicated by
Unknown) in port 26.
Link Status (Read-only)
Indicates whether or not there is a physical connection from this port to
another 10BASE-T or 100BASE-TX/FX device. One of the following
values displays:
Link There is a link signal present and a valid physical connection to
another device.
No Link There is no link signal present and no valid physical
connection to another device.
Firmware Revision: XX.XX.XX
High Speed Interface Configuration
23141-24
Device Type: 2E48-27R
BOOTPROM Revision: XX.XX.XX
Port 25
FE-100TX
Link
100Base-TXFD
[Auto-Negotiation]
[100Base-TXFD] [Disabled]
RETURN
2E48-27R LOCAL MANAGEMENT
Event Message Line
SAVE
Port Type
Link Status
Current Oper. Mode
Desired Oper. Mode
Advertised Ability
Port 26
Unknown
N/A
[N/A]
[N/A]
[N/A]
EXIT