Cabletron Systems 6000 Switch User Manual


 
ix
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
THE GPIM-01 AND GPIM-09 GIGABIT ETHERNET MODULES
USE CLASS 1 LASER TRANSCEIVERS.
READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING
THESE MODULES.
The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop
eliminates the need for maintenance checks or adjustments. The output is factory set, and does not allow any user
adjustment. Class 1 Laser transceivers comply with the following safety standards:
21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA).
IEC Publication 825 (International Electrotechnical Commission).
CENELEC EN 60825 (European Committee for Electrotechnical Standardization).
When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit
of all three standards. Class 1 levels of laser radiation are not considered hazardous.
SAFETY INFORMATION
CLASS 1 LASER TRANSCEIVERS
LASER RADIATION AND CONNECTORS
When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power
exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10
-6
watts.
Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The
maximum radiance from the optical port (under worst case conditions) is
0.8 W cm
-2
or 8 x 10
3
W m
2
sr-1.
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output
increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.