Cabletron Systems 6E122-26 Switch User Manual


 
The Interface Statistics Screen
6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide 5-97
OutOctets (Read-only)
This field displays the total number of octets (bytes) that have been
transmitted from the interface.
OutUnicast (Read-only)
The OutUnicast field displays the total number of packets transmitted that
were sent to a single address.
OutNonUnicast (Read-only)
This field displays the total number of frames transmitted to a broadcast
or multicast address.
OutDiscards (Read-only)
The OutDiscards field displays the total number of outbound frames that
were discarded, even though the frames contained no errors. This field
may increment, because the switch needed to free up buffer space, or the
switch was being overutilized.
OutErrors (Read-only)
This field displays the total number of outbound frames discarded
because they contained errors. This field represents the total number of
errored frames, regardless of the cause of the error.
OutQLen (Read-only)
The OutQLen field displays the length of the packet queue. The field
represents the total number of packets that can be contained in the queue.
Address (Read-only)
This field displays the MAC Address of the interface that is currently
being displayed.
Last Change (Read-only)
This field displays the last time that the interface was reset.
Admin Status (Read-only)
This field displays the current status of the interface. If this field displays
“Testing”, no frames may be passed on this interface.