Cabletron Systems 6E122-26 Switch User Manual


 
Chapter 4: Troubleshooting
4-6 6E122-26, 6E132-25, 6E123-26 and 6E133-25 User’s Guide
4.3 TROUBLESHOOTING CHECKLIST
If the 6E12X-26 or 6E13X-25 is not working properly, refer to Table 4-4
for a checklist of possible problems, causes, and recommended actions to
resolve the problem.
Table 4-4 Troubleshooting Checklist
Problem Possible Cause Recommended Action
All LEDs are OFF.
Loss of power to the
6C105 chassis.
Check the proper connection
of the power cable and its
access to a live outlet.
6E13X-25 or 6E12X-26
not properly installed.
Check the installation.
No Local
Management
Password screen.
Autobaud enabled. But
baud rate has not yet
been sensed.
Press ENTER (RETURN)
(may take up to four times).
Terminal setup is not
correct.
Refer to Chapter 5 for proper
setup procedures.
Improper console cable
pinouts.
Refer to Appendix A for
proper console port pinouts.
Cannot contact the
6E132-25 or
6E122-26 from
in-band
management.
Improper Community
Names Table.
Refer to Chapter 5
for Community Names Table
setup.
6E12X-26 or 6E13X-25
does not have an IP
address.
Refer to Chapter 5 for IP
address assignment
procedure.
Port is disabled. Enable port.
No link to device. Check link to device.
Port(s) goes into
standby for no
apparent reason.
6E12X-26 or 6E13X-25
detects a looped
condition.
Review network design and
delete unnecessary loops.
User parameters (IP
address, Device and
Module name, etc.)
are lost when the
6E12X-26 or
6E13X-25 is
powered down or
the front panel
RESET button is
pressed.
Mode switch (7), NVRAM
Reset, was changed
sometime before either
cycling power or
pressing the RESET
button, causing the
user-entered parameters
to reset to factory default
settings.
Reenter the lost parameters
as necessary. Call the
Cabletron Systems GCC if
problem continues.