Chapter 4
4-34
4.5.4 Procedure after Replacing the Head Management Sensor
0012-6394
Since the distance between the head management sensor and the carriage unit varies among printers, the optical
axis is factory-adjusted to adjust the non-discharging detection position. When you have replaced the head
management sensor or performed assembly/reassembly of surrounding parts that can change the distance
between the head management sensor and the carriage unit, reasjustment is required
Peform the readjustment in the service mode.
Service mode : SERVICE MODE > ADJUST > NOZZLE CHK POS.