Setting Various Functions
134
Reducing Flickering
[Deflicker]
This function adjusts the image display in
order to reduce flickering in the projected
image.
MENU > [System settings] > [Other settings] >
[Deflicker]
• When deflicker is performed, the image
adjustment screen is projected for approx-
imately 20 seconds.
• To cancel deflicker, press the POWER but-
ton.
Gamma Restore
[Gamma restore]
The gamma characteristic of the LCD
panel inside the projector can be cor-
rected.
MENU > [System settings] > [Other settings] >
[Gamma restore]
• If Gamma restore is performed, the pro-
jected image will be adjusted for a period
of approximately 150 seconds.
• To stop Gamma restore, press the POWER
button or the EXIT button (WX6000 /
SX6000).
HDMI Component
Digital PC Analog PC
Off Deflicker adjustment is not per-
formed.
Adjust Select [Deflicker] to adjust. The fol-
lowing screen appears.
OK Deflicker is performed.
Cancel Deflicker is not performed.
• Deflicker can only be used when the
lamp has been on for approximately
30 minutes or longer.
• Be aware that deflicker may be
unable to eliminate flickering in some
cases.
HDMI Component
Digital PC Analog PC
Off Returns to the factory default with-
out performing Gamma restore.
Adjust Performs Gamma restore and
applies the result.
OK Gamma Restore is per-
formed.
Cancel Gamma Restore is not
performed.
• Gamma restore can be performed
once approximately 30 minutes have
elapsed after the lamp flashes.
• Be aware that if Gamma restore
adjustment is performed, the color
quality of the projected image may