Celestron AP8000 Server User Manual


 
38
IV. Hardware Setup
IV. Hardware Setup
AP8000 Hardware Reference Guide
Power Supply Info
Output Voltage Regulation, Ripple, and Noise
Output Current Capacity
Input Voltage
Input Current
Safety
The power system meets all applicable clauses for UL 1950 2nd edition without
D3 deviations. The power system passes all tests for CUL and TUV safety.
EMI
The power system, operating with resistive load, meets FCC class B and CISPR 22
class B conducted limits.
Power Supply Information
Output Voltage Limits (Vdc) Ripple/Noise
Output Min Nom Max Maximum
1 3.17V 3.30V 3.46V 50mV
p-p
2 4.80V 5.00V 5.25V 50mV
p-p
3 11.40V 12.00V 12.60V 120mV
p-p
4 -4.75V -5.00V -5.25V 120mV
p-p
5 -11.40V -12.00V -12.60V 120mV
p-p
* Total output power for 3.3V and 5V combined shall be 210W
Output Nom (Vdc) Max (A) Min (A)
1 3.3V *30.0 0.0
2 5.0V *40.0 3.0
3 12.0V 15.0 0.5
4 -5.0V 0.5 0.0
5 -12.0V 0.5 0.0
Range Min (V) Nom (V) Max (V)
Range 1 90 120 132
Range 2 180 230 264
Input Voltage Max In Cur. Max Inrush Cur.
Range 1 10 100Ap-p
Range 2 5 200Ap-p