Chapter 2 Cabling and Troubleshooting the CSS
Connecting the Power Cord
Warning
Only a DC power source that is isolated from AC mains with reinforced
insulation, and that complies with the other safety extra-low voltage (SELV)
requirements in UL1950, CSA 950 3rd Edition, EN 60950, and IEC950, can be
connected to a Cisco 11506 system. This requirement ensures that in a
catastrophic power source fault condition, hazardous voltages are not present
on power terminals and connectors.
Warning
This unit might have more than one power supply connection; all connections
must be removed completely for you to completely remove power from the unit.
To connect each CSS 11506 DC power supply to a power source:
1. On the power supply, ensure that the CSS power switch is in the O (off)
position.
2. Locate the power supply DC terminal block, as shown in Figure 2-15.
Figure 2-15 Location of CSS 11506 DC Power Supply Connectors
1 Power supply LEDs 3 Terminal block (–, +, and )
2 Power switch
CSS5-10M-2GE
Gigabit Ethernet
GE 1
GE 2
LINK
LINK
1
2
3
CSS5-10M-16FE
1
2
3
4
5
6
PS1
PS2
PS3
7
DISCONNECT ALL
POWER SOURCES
BEFORE SERVICING
CAUTION
8
100-240V
~
5A 50-60 Hz
AC
OK
DC
OK
-48/-60V
10/8A
I/P
OK
DC
OK
AC
OK
DC
OK
59546
3
1 2
59199