Cisco Systems C220 Server User Manual


 
3-4
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Chapter 3 Maintaining the Server
Status LEDs and Buttons
Rear Panel LEDs and Buttons
Figure 3-2 shows the rear panel LEDs and buttons. Table 3-2 defines the LED states.
Figure 3-2 Rear Panel LEDs and Buttons
1 Power supply fault LED 5 1-Gb Ethernet link speed LED
2 Power supply AC OK LED 6 1-Gb Ethernet link status LED
3 1-Gb Ethernet dedicated management link
status LED
7 Rear Identification button/LED
4 1-Gb Ethernet dedicated management link
speed LED
Ta b l e 3-2 Rear Panel LEDs, Definitions of States
LED Name State
Power supply fault Off—The power supply is operating normally.
Amber, blinking—An event warning threshold has been reached, but the power
supply continues to operate.
Amber, solid—A critical fault threshold has been reached, causing the power
supply to shut down (for example, a fan failure or an over-temperature condition).
Power supply AC OK Off—There is no AC power to the power supply.
Green, blinking—AC power OK, DC output not enabled.
Green, solid—AC power OK, DC outputs OK.
1-Gb Ethernet dedicated
management link speed
Off—link speed is 10 Mbps.
Amber—link speed is 100 Mbps.
Green—link speed is 1 Gbps.
1-Gb Ethernet dedicated
management link status
Off—No link is present.
Green—Link is active.
Green, blinking—Traffic is present on the active link.
PSU1PSU1 PSU2PSU2PSU1 PSU2
1
2 3 4 75 6
331692