Cisco Systems C220 Server User Manual


 
3-38
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Replacing a Cisco Flexible Flash Card
This section includes the following topics:
Overview of the Pre-Installed Cisco Flexible Flash Card, page 3-38
Enabling a Cisco Flexible Flash Virtual Drive, page 3-39
Booting a Cisco Flexible Flash Virtual Drive, page 3-39
Monitoring and Managing a Cisco Flexible Flash Card, page 3-40
Cisco Flexible Flash Card Replacement Procedure, page 3-40
Overview of the Pre-Installed Cisco Flexible Flash Card
The internal slots for these cards are on the circuit board of PCIe riser 2 (see Figure 3-23).
Note Dual cards are supported only with CIMC 1.5(1) or later. With releases earlier than CIMC 1.5(1), only
a single card is supported and it must be in slot SD1.
The Cisco Flexible Flash card is pre-installed with three software bundles, each on one of four
preconfigured virtual drives (VDs). The fourth VD allows you to install an OS or embedded hypervisor.
The VDs are configured as follows:
1. Cisco UCS Server Configuration Utility (SCU).
2. Hypervisor (HV). This is a VD that you can use for your own purposes.
3. Cisco Drivers (Drivers).
4. Cisco Host Upgrade Utility (HUU).
Figure 3-23 Cisco Flexible Flash Card Slots on PCIe Riser 2
1 Slot SD2 2 Slot SD1
FAN1
FAN1
FAN1
FAN2
FAN2
FAN2
FAN3
FAN3
FAN3
FAN4FAN4
FAN4
FAN4
FAN5
FAN5
FAN5
PSU2
PCIe1
PCIe2
PSU1
CPU1
CPU2
SAS1
SAS2
SAS1
SAS2
331714
1
2