Cisco Systems 2020 Switch User Manual


 
2-28 LightStream 2020 Installation Guide
Basic LS2020 Configuration Tasks
Network Processor Default IP Router: 197.110.175.2
Chassis configuration contains 1 network processor.
Network processor’s on-board Ethernet LAN interface is attached to an external
Ethernet LAN.
Is the chassis and network processor information correct? (Y/N)? [Y] Y
If you confirm that the configuration data you have entered in this step is correct by
responding Y to this query, the script continues with the trunk port configuration query
below.
On the other hand, if you wish to change any configuration data, answer “N” at the chassis
and network processor information query and repeat this step in its entirety. You will be
prompted by the configuration script to re-enter all the applicable network management
information for your LS2020 switch.
Configure trunk port information (Y/N)? [N] N
Creating minimum configuration database...done.
Similarly, if you respond N to the above trunk port configuration query, the system reports
that it is creating a minimum configuration database and that you have completed the basic
configuration procedure.
If you respond “Y” to the trunk port configuration query, proceed with Step 6 below.
Step 5 If your LS2020 switch contains a redundant network processor, continue with the
configuration script, as follows:
Does the chassis contain redundant network processors (Y/N)? [N] Y
Configure the Chassis Secondary IP address (for use by a network processor
while acting as backup). This address should be an address on the subnetwork
connecting all network processors in your network.
Chassis Secondary IP Address [a.b.c.d]: 192.1.1.12
Your system may be attached to an external Ethernet LAN by means of the
on-board Ethernet LAN interface on the network processors.
In a redundant configuration with two network processors, if the network
processors are each attached to an external Ethernet LAN by means of the
on-board Ethernet LAN interfaces, the two network processors should each be
attached to the same Ethernet LAN.
If the network processors are attached to an Ethernet LAN, you will be asked
to provide the IP address and IP subnet mask of the network processors'
on-board Ethernet LAN interface.
Are the two network processors attached to an Ethernet LAN (Y/N)? [N] Y
In a redundant configuration with two network processors, the primary
(active) network processor provides the logical connection to the attached
Ethernet LAN. Thus you will be asked to specify only one IP address and mask.
Configure the IP address for the network processors' Ethernet LAN interface.
Network Processor Ethernet IP Address [a.b.c.d]: 197.112.23.12
Configure the IP subnet mask for the network processors' Ethernet LAN
interface.