Displays CYRAQ™ 21
2.3.2 Panel Mounting the Monitor
1. Panel cutout is 356mm H x 440mm W for landscape installation (Figure 6).
2. Install CYRAQ in panel cutout. Ensure all studs clear cutout opening and Poron
™
gasket on the rear of the unit is flush against panel (critical for NEMA
compliance).
3
NOTE: Steps 3 & 4 require a second person
3. Align studs on the CYRAQ with the holes in mounting plate from the rear of
panel (as seen in Figure 6).
Important!
Do not exceed 30 in/lbs when tightening mounting nuts.
4. Also from rear of the panel, second person must install and tighten the fourteen
10-32 mounting nuts.
Figure 6: Panel-Mount Landscape Installation
CyberResearch, Inc. 17