CYRAQ™ 21 CyberResearch
®
Displays
2.4 Flush Panel-Mounting: CPxF/CPxR 21A
Prior to performing subsequent steps, ensure the panel-mounting location (including
panel thickness) is suitable for the C
YRAQ 21, and meets Environmental requirements in
Specifications section.
3
NOTE: Panel thickness should not exceed: .55" (14.1mm) Suggested panel thickness
is calculated based on standard CYRAQ 21 parts and dimensions, custom units may not
meet these specifications. Poron
™
gasket is installed by CyberResearch, Inc. on CPBF &
CPBR 21 models.
2.4.1 Panel Mounting the Monitor
1. Panel cutout is 405mm H x 489mm W for landscape installation (Figure 7).
2. Install the display in panel cut out. Ensure all studs clear cutout opening and
Poron
™
gasket on the rear of the unit is flush against panel (critical for NEMA
compliance).
3
NOTE: Steps 3 & 4 require a second person
3. Align studs on the rear of display with the holes in mounting plate from the rear
of panel (as seen in Figure 7).
Important!
Do not exceed 30 in/lbs when tightening mounting nuts.
4. Also from rear of the panel, second person must install and tighten the fourteen
10-32 mounting nuts.
See Next Page For Illustration
18 ©Copyright 2005 CyberResearch, Inc