10
QuickScan 6000/6000 Plus
IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E I/F Selection
Scan this label to enable the IBM 468x/9x Port 9x interface.
IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E Settings
Data Format: Send As Code 39 — converts bar code data (UPC/EAN,
add-ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39
format before sending the data to the host.
These settings are for IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E inter-
face ONLY.
Limit Command Set — is an option that causes the scanner to ignore
'enable scanner' and 'disable scanner' commands sent from the host.
Transmit Unsolicited Status
1
— when enabled, this option causes the
scanner to transmit a status message to the host upon receipt of an
"SNRM".
SET ----------------------------------------------
SEND AS CODE 39 ----------------
DON'T SEND AS CODE 39 --------
ENABLE LIMIT COMMAND SET -----
DISABLE LIMIT COMMAND SET -----
TRANSMIT UNSOLICITED STATUS ---
DON'T TRANSMIT UNSOLICITED STATUS---
END ----------------------------------------------
1 For this IBM interface, the setting for Unsolicited Status is normally Disabled.
D
ATA
F
ORMAT