Datalogic Scanning 6000 Barcode Reader User Manual


 
80
QuickScan 6000/6000 Plus
General Features
The following section contains the general features that are common to all
interfaces. These features allow modification of the scanner's behavior to
accomodate user preferences.
Good Read Beeper Settings
These labels provide options for the scanner's audible 'beep' signal.
Audible Signal — enables/disables the beep upon completion of a
good read.
NOTE
It is strongly recommended that this feature remain enabled, as the
good read beep provides the best scanning status feedback to the
user. Error tones are always enabled and cannot be disabled.
Power-up Beep — when enabled, beeps upon scanner power-up.
Beeper Volume — allows setting of the beeper to NORMAL or HIGH
volume.
Good Read Beep Duration — can be adjusted to short (100msec),
medium (250msec), or long (500msec) durations.
When to Beep — may be programmed to announce a 'good read'
upon completion of one of the following events:
Decode of a bar code's label
Transmission from the scanner to the host
CTS activation at the host terminal (RS-232 models ONLY)