Software Control
XON/XOFF — this is software handshaking that allows the host to
control data transmission. If the host sends an XOFF command to
the scanner, the scanner will not send the bar code data until it
receives an XON command from the host. If the host sends the
XOFF command during data transmission, the host will receive
additional characters for no more than 2msec
1
.
NOTE
Hardware/software controls are mutually exclusive. Enable only one
of these features at a time, as enabling multiple controls can produce
unpredictable results.
SET ----------------------------------------------
DISABLE HARDWARE CONTROL-----
ENABLE CTS/RTS FLOW CONTROL --
ENABLE CTS SCAN CONTROL ----
ENABLE XON/ XOFF ----------------
DISABLE XON/XOFF ----------------
END ----------------------------------------------
1 Varies slightly depending upon baud rate selected.