82
QuickScan 6000/6000 Plus
Read Verification
QuickScan 6000/6000 Plus
programming has been improved to allow selec-
tion of read verification "minimum read" requirements by symbology type,
as well as universally. This means that the scanner needn't waste valu-
able time verifying high-confidence symbologies, while offering the
security of multiple read verification on less reliable codes.
NOTE
The more times the scanner is required to read and compare the
bar code's data, the longer it will take to complete a good read
cycle.
Universal Read Verification
To set read requirements universally (read requirements will be in effect
for all symbologies), scan one of the selections below for one, two, three
or four reads required before a bar code's data can be transmitted to the
host.
NOTE
DO NOT scan SET or END bar codes when programming these
features. Programming mode is automatically entered and exited
when one of the four bar codes below are scanned.
Verify 1 Read, all symbologies
Verify 2 Reads, all symbologies
Verify 3 Reads, all symbologies
Verify 4 Reads, all symbologies
U
NIVERSAL
R
EAD
V
ERIFICATION