Datalogic Scanning 6000 Barcode Reader User Manual


 
Programming Guide 47
Symbology Options Overview
Enable All Symbologies — allows the scanner to auto-discriminate between
all the symbologies in this list. Use this selection only if you must constantly
read a wide variety of symbologies. Turn to the following pages for
enabling additional symbology specific options.
Disable All Symbologies — disables all symbologies
1
. The scanner will only
recognize the programming labels contained in this manual while you are
in Programming Mode.
Enable UPC/EAN — tells the scanner to recognize UPC-A, UPC-E, EAN-
8, and EAN-13. If you enable this symbology, additional options for
symbology expansion and reading add-ons are available. Allows selection
of expansion and add-on options.
Enable Code 39 — selects Code 39 as an active symbology. Allows selection
of Check Digit, Start/Stop and Single Digit options.
PharmaCode 39 — is a symbology subset of Code 39. Enabling PharmaCode
39 selects this special Italian code as the active Code 39 symbology
(superceding standard Code 39 features).
NOTE
Standard Code 39 must be enabled before PharmaCode can be
enabled.
Enable Interleaved 2 of 5 — selects Interleaved 2 of 5 as an active
symbology. Allows change of Check Digit or label format (fixed
or variable length) options.
Enable Standard 2 of 5 — selects Standard 2 of 5 as an active
symbology. Options for this symbology are similar to Inter-
leaved 2 of 5 features.
1 Code 128 is always active for the purpose of reading programming bar code labels; however,
the scanner does not transmit data to the host when in Programming Mode. Scanning the
DISABLE ALL SYMBOLOGIES label will disable Code 128 transmission to the host.