REFERENCES
125
5
5.3.3 Address Stamping
It is possible to include the reader address in the message sent to the host. The
reader Address Stamping parameter consists of a 4-digit number in the range
0000-1999.
For message output format, refer to par. 5.3.
5.3.4 Address Delimiter
The Address Delimiter allows a character to be included to separate the reader
Address stamping field from the next field in the message. Any character can be
included in the hexadecimal range from 00 to FE.
For message output format, refer to par. 5.3.
5.4 POWER SAVE
5.4.1 Sleep State
This mode allows the
µ
P in the reader to enter a “Sleep” state for minimum power
consumption. For D-series readers, this command is only valid when hardware
trigger type is selected.
Before entering Sleep mode, the following are verified:
•
no commands coming from Host
•
no data being transmitted to Host
•
Enter Sleep Timeout ended (see par. 5.4.2)
To exit Sleep mode press the trigger.
Enabling the Sleep state implements Standby mode for CCD devices, see par. 5.4.3.
For M-series readers, sleep state is entered immediately after reading a code and is
not configurable. To exit Sleep mode press the trigger.
5.4.2 Enter Sleep Timeout
For readers that have the Sleep state enabled, this timeout determines when the
reader will enter this state.