A
CODE SELECTION (continued)
DESCRIPTION STRING
enable ISBN
AP1
enable ISSN
AP2
enable ISBN and ISSN
AP3
ISBN Conversion codes
disable ISBN and ISSN
AP0
Code 39 disable Code 39 family
AB0
Standard no check digit control
AB11
check digit control and transmission
AB12
check digit control without transmission
AB13
Full ASCII no check digit control
AB21
check digit control and transmission
AB22
check digit control without transmission
AB23
CIP 39
AB3
Code 32
AB4
code length
AB*xxxx
2/5 disable Code 2/5 family
AC0
Interleaved 2/5 no check digit control
AC11xxxx
check digit control and transmission
AC12xxxx
check digit control without transmission
AC13xxxx
Normal 2/5 5 bars no check digit control
AC21xxxx
check digit control and transmission
AC22xxxx
check digit control without transmission
AC23xxxx
Industrial 2/5 (IATA) no check digit control
AC31xxxx
check digit control and transmission
AC32xxxx
check digit control without transmission
AC33xxxx
Matrix 2/5 3 bars no check digit control
AC41xxxx
check digit control and transmission
AC42xxxx
check digit control without transmission
AC43xxxx
CIP/HR
AC5
xxxx
= ASCII numbers that define the code length where:
First 2 digits = minimum acceptable code length.
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.