REFERENCES
133
5
5.9.3 Copy OM-GRYPHON™
Procedure:
Using the
slave
reader and its OM-GRYPHON™ cradle, read the Restore
Default barcode, set the radio address, and then read the RS232 interface
barcode from chapter 4 of this manual or from the Quick Reference Manual.
Connect the
master
OM-GRYPHON™ and the
slave
OM-GRYPHON™ (cradle
to be configured) together through two RS232 serial interface cables and
external power supply. Accessory cables and power supply are available from
your Datalogic distributor to provide this connection.
RS232 Cables: CAB363 & CAB364
or CAB320 & CAB328
Power Supply: PG12
Read the Configuration Copy barcode below with a reader. Then place it onto
the
master
OM-GRYPHON™ cradle.
Copy Configuration
i;;k
i;;k
i;;k
$+ZZ3$-
The configuration will be copied from the master OM-GRYPHON™ to the slave
OM-GRYPHON™. The reader signals the end of the procedure with a series of
beeps.
Repeat the procedure above to configure other slave cradles.
Note:
The master OM-GRYPHON™ can be configured for any interface.