Datamax DGL Printer User Manual


 
32
Chapter 3
received, the printer will respond with the internal A-D sensor values, see
table below. To repeat the display of values, send the printer a ‘SPACE’ (20
hexadecimal). Send <ESC> to terminate the function.
(Not supported.)
STX Z - Print Internal Information
This command prints the configuration. To capture all printed information, use
labels as wide as the print width and at least 4 inches (102mm) long.
(Not
supported.)
STX z - Pack Module
This command causes the printer to reclaim all storage space associated with
all deleted files on the specified module. A Flash Module cannot be packed.
(Not supported.)
STX b - Set Cutter signal time
(Obsolete System Command.)
STX C - Copy Module
(Obsolete System Command.)
STX D - Memory Dump (Test Mode Only)
(Obsolete System Command.)
STX d - Set Printer to double buffer mode
(Obsolete System Command.)
STX g - Internal Batch Software Mode
(Obsolete System Command.)
STX N - Enter Internal Batch
(Obsolete System Command.)
STX s - Set Printer to single buffer mode
(Obsolete System Command.)
e - Recall Printer Configuration
This command recalls a previously stored printer configuration. It is highly
recommended that only one Recall Printer Configuration command be used
per label, and that it be used at the beginning of the label; otherwise,
unpredictable results will occur. (Printer Configurations may be stored using
the Extended System Commands or the printer’s menu system.)
(Not
supported.)