Datamax DGL Printer User Manual


 
52
Appendix A
CONTROL CODES Allows the operator to change
the prefix of the software
commands interpreted by the
printer.
*STANDARD CODES
ALTERNATE CODES
ALTERNATE CODES 2
ALTERNATE CODES 3
PPI/DGL SETUP
Control
Codes
*Standard, Alternate1,
Alternate2, User-defined
FEEDBACK CHARACTERS Returns a Hex 1E, [RS], after
each label successfully prints,
and a Hex 1F, [US], after
each batch of labels is
printed.
ENABLED, *DISABLED
PPI/DGL SETUP
Feedback Chars
Enable, *Disable
ESC SEQUENCES Allows data containing invalid
ESC control code sequences
to be processed.
ENABLED, *DISABLED
N/A
HEAT COMMAND
SPEED COMMANDS
Allows the user to disable the
DPL Heat and Speed
Commands.
ENABLED, *DISABLED
PPI/DGL SETUP
Heat
Cmd, Speed Cmd
*Process, Ignore
Table 5. Communications Menu
Datamax Setting Description PTX Setting
Table 6. Diagnostics Menu
Datamax Setting Description PTX Setting
HEX DUMP MODE Prints data and instructions
received from the host rather
than interpreting them as
label formats
ENABLE, *DISABLE
DIAGNOSTICS
Hex
Dump Mode
Enable, *Disable
OPTIONS TESTING Tests currently installed
options
N/A
PRINT TEST RATE (min) The number of minutes to
delay between the printing of
batches of labels in Quick
Test Mode.
*000 (0-120)
N/A
SENSOR READINGS
RIBBON SENSOR LIMITS
Analog Sensor readings are
displayed.
CALIBRATE CTRL
Media
Profile
Print Profile