Dell 180 Computer Hardware User Manual


 
Beep Codes and Error Messages 3-5
Stepping of
CPU1 is less
than sA1 -
System halted.
Wrong microprocessor
installed in
PROCESSOR1 socket.
Replace microprocessor
with sA1 stepping or
greater.
Stepping of
CPU2 is less
than sA1 -
System halted.
Wrong microprocessor
installed in
PROCESSOR2 socket.
Replace microprocessor
with sA1 stepping or
greater.
Stepping of
CPU is less
than sA1 -
System halted.
Wrong microprocessor
installed in system.
Replace microprocessor
with correct sA1 step-
ping or greater.
Nonidentical
CPUs - System
halted.
Cache memory sizes of
the two Pentium Pro
microprocessors do not
match.
Replace one of micropro-
cessors so that cache size
of both microprocessors
matches.
Invalid CPU
speed detected
- Check speed
jumpers.
System halted.
The microprocessor
speed detected is neither
180 MHz or 200 MHz.
Check microprocessor
speed jumpers.
Power supply
paralleling
board firm-
ware download
failed
System back-
plane firm-
ware download
failed
Server-management bus
cable connection to
SCSI backplane board is
loose.
Check server-
management bus cable
connections to system
board (labeled “SMB
BACKPLANE”) and
SCSI backplane (labeled
“SMB”). Turn off and
then restart system.
Embedded
server manage-
ment firmware
download
failed
Embedded server
management memory
temporarily corrupted.
Turn off and then restart
the system.
Table 3-2. System Error Messages (continued)
Message Definition Action