Dell 745N Personal Computer User Manual


 
Blink Virtual Disk
This command allows you to locate the array disks included in a virtual disk by blinking the LEDs on the array disks. This command automatically cancels after a
shortdurationsuchas30or60seconds.
Unblink Virtual Disk
This command allows you to cancel the Blink Virtual Disk command before the 30- or 60-second time limit has been reached.
Disk Commands
Initialize
Initialize any array disk before you use it.
Perform the following procedure on any array disk on a supported RAID controller.
1. Right-click the array disk that you want to initialize.
2. Click Initialize.
The status of the disk displays Initializing in the right pane until the operation is finished.
Format
The Format command performs a low-level formatting of the array disk. To format the array disk, perform the following steps:
1. Right-click the disk that you want to format.
2. Click Format.
The right pane shows the status of the format. The status displays Formatting until the operation is finished.
Rebuild
The Rebuild command is enabled only when a disk has failed. You can rebuild only on failed disks in redundant arrays (RAID 1 or RAID 5) by performing the
following steps:
1. Right-click the failed disk that you want to rebuild.
2. Click Rebuild.
In the right pane, the status of the disk is Rebuilding and a progress bar shows the percentage of completion.
NOTE: This procedure only applies to drives on an external SCSI enclosure.
NOTE: This procedure only applies to drives on an external SCSI enclosure connected to an external storage configuration system.
NOTICE: All data on the virtual disk is lost when the disk is initialized.