Dell 2161DS Switch User Manual


 
24 Installation
www.dell.com | support.dell.com
Figure 2-8. PEM Rack Installation
Adding a Cascade Switch (Optional)
You can add your cascade switches in the 2161DS Console Switch system. Each ARI port will then
accommodate up to 16 servers, increasing the total number of servers you can add to 256.
To add a cascade switch (optional):
NOTE: The 2161DS Console Switch does not support the EL80-DT.
1
Mount the switch into your rack. Locate a CAT 5 cable to connect your 2161DS Console
Switch unit to the SIP for your switch.
2
Attach one end of the CAT 5 cabling to the RJ45 connector on the SIP. Connect the other
end of the CAT 5 cable to the desired port on the back of your 2161DS Console Switch unit.
3
Attach the keyboard, monitor, and mouse connectors of the SIP to a user port on your switch.
4
Connect the servers to your cascaded switch according to the switch manufacturer's
recommendations.
5
Repeat steps 1-4 for all the cascade switches you wish to attach to your 2161DS Console
Switch system.
NOTE: The 2161DS Console Switch supports only 1 switch per ARI port. You cannot tier another switch
under this first switch.
NOTE: When cascading with a 2161DS Console Switch, an 8-port or 16-port analog console switch is not
supported as the primary unit in a cascaded configuration. The 2161DS Console Switch must be the
primary unit.