120 RACADM Subcommand Details
Table 2-33 describes the setled subcommand options.
Example for CMC
• racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of
a multi-slot server.
• racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the
server in slot 1.
Example for iDRAC6
• racadm setled -l 1
LED state was set successfully.
Table 2-33. setled Subcommand Options
Option Description
-m <module>
NOTE: This option is applicable for CMC only.
Specifies the module whose LED you want to configure.
<module> can be one of the following:
•
server-n
where
n
=1–16
•
switch-n
where
n
=1–6
• cmc-active
• chassis
-l <ledstate> Specifies whether the LED should blink.
<ledstate> can be one of the following:
•
0
— no blinking
•
1
— blinking