Dell PC7048P Switch User Manual


  Open as PDF
of 1730
 
RMON Commands 1465
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field Description
Alarm Alarm index.
OID Monitored variable OID.
Last Sample
Value
The statistic value during the last sampling period. For example,
if the sample type is delta, this value is the difference between the
samples at the beginning and end of the period. If the sample
type is absolute, this value is the sampled value at the end of the
period.
Interval The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds.
Sample Type The method of sampling the variable and calculating the value
compared against the thresholds. If the value is absolute, the
value of the variable is compared directly with the thresholds at
the end of the sampling interval. If the value is delta, the value of
the variable at the last sample is subtracted from the current
value, and the difference compared with the thresholds.
Startup Alarm The alarm that may be sent when this entry is first set. If the first
sample is greater than or equal to the rising threshold, and startup
alarm is equal to rising or rising and falling, then a single rising
alarm is generated. If the first sample is less than or equal to the
falling threshold, and startup alarm is equal falling or rising and
falling, then a single falling alarm is generated.
2CSPC4.XCT-SWUM2XX1.book Page 1465 Monday, October 3, 2011 11:05 AM