Dell
39
PowerEdge R210 II Technical Guide
5
ASSR0CBL
Add-in SAS/SATA RAID card, RAID 0 (PERC S300)
3
4
6
ASSR1CBL
Add-in SAS/SATA RAID 1 (PERC S300)
2
2
7
ASSR5CBL
Add-in SAS/SATA RAID card, RAID 5 (PERC S300)
3
4
8
ASSR10CBL
Add-in SAS/SATA RAID card, RAID 10 (PERC S300)
4
4
9
ASSCBL
Add-in SAS/SATA RAID card, No RAID
(PERC H200)
1
4
10
ASSR0CBL
Add-in SAS/SATA RAID card, RAID 0 (PERC H200)
2
4
11
ASSR1CBL
Add-in SAS/SATA RAID card, RAID 1 (PERC H200)
2
2
SAS/SSD
RAID
12
ASSR10CBL
Add-in SAS/SSD RAID card, RAID 10
(PERC H200)
4
4
Note: Configurations that require more than 3 hard drives will be available in Q2 2011.
Additional restrictions for RAID configurations are listed as follows:
Hard drives must be all 3.5‖ or 2.5‖ (2.5‖ drives available Q2 2011)
Must be all SAS or all SATA or all SSD
No Mixed Hard drives allowed
SSD support requires PERC H200
PERC S300 does not support SSD
The PERC S300 does not support the following virtualization solutions:
Microsoft
®
Hyper-V™ server 2008 x64 (download version)
Microsoft Windows Server
®
2008 x64 (Hyper-V™ role enabled)
Microsoft
Windows Server 2008 SP2 x64 (Hyper-V™ role enabled)
Microsoft
Windows Server 2008 R2 (Microsoft
Windows
®
7 includes SP2 bits) x64 (Hyper-V
role enabled)
The PERC S300 does not support Linux
®
operating systems or VMware
®
virtualization software.
12.4 Optical Drives
The R210 II supports one SATA interface DVD-ROM or DVD+/-RW.
12.5 Tape Drives
External tape drives and tape libraries are supported. No internal tape drive support is available.
For more information on supported tape drives and tape libraries, see Dell.com/Storage.