Dell R820 Computer Hardware User Manual


 
Error Code Message Information
Action Check if the cable is present, then reinstall or reconnect.
MEM0000
Message Persistent correctable memory errors detected on a memory device
at location(s) <
location
>.
Details This is an early indicator of a possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help .
MEM0001
Message Multi-bit memory errors detected on a memory device at location(s)
<
location
>.
LCD Message Multi-bit memory error on <
location
>. Re-seat memory.
Details The memory module has encountered an uncorrectable error. System
performance may be degraded. The operating system and/or
applications may fail as a result.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0007
Message Unsupported memory configuration; check memory device at location
<
location
>.
LCD Message Unsupported memory configuration. Check memory <
location
>.
Details The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM0701
Message Correctable memory error rate exceeded for <
location
>.
Details The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0702
Message Correctable memory error rate exceeded for <
location
>.
LCD Message Correctable memory error rate exceeded for <
location
>. Re-seat
memory.
Details The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1205
Message Memory mirror redundancy is lost. Check memory device at
location(s) <
location
>.
131