Dell R820 Computer Hardware User Manual


 
Error Code Message Information
LCD Message Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue persists,
see Getting Help.
PST0128
Message No memory is detected.
LCD Message No memory is detected. Inspect memory devices.
Details System BIOS was unable to detect memory in the system.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
PST0129
Message Memory is detected, but is not configurable.
LCD Message Memory is detected, but is not configurable. Check memory devices.
Details System BIOS detected memory, but was unable to configure the
memory for system operation.
Action Compare system memory installation to supported system memory
configurations.
PSU0001
Message Power supply <
number
> failed.
LCD Message PSU <
number
> failed. Check PSU.
Action Remove and reinstall the power supply. If the issue persists, see
Getting Help.
PSU0002
Message A predictive failure detected on power supply <
number
>.
LCD Message Predictive failure on PSU <
number
>. Check PSU.
Details System performance and power redundancy may be degraded or
lost.
Action Remove and reinstall the power supply at the next service window. If
the issue persists, see Getting Help.
PSU0003
Message The power input for power supply <
number
> is lost.
LCD Message Power input for PSU <
number
> is lost. Check PSU cables.
Details The power supply is installed correctly but an input source is not
connected or is not functional.
Action Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
134